Series 42 Tab/Screw Type Terminal Blocks
Features
Series 42 terminal blocks are designed to meet the VDE and CEE requirements for major appliance connections, the wiring from the power source must be connected to these appliances through a screw connector, while quick-connect tabs can be used internally.
They are available in 2, 3, 4 & 6 poles and are supplied with two fixing holes (type L) as standard, or alternatively, 3 and 4 pole versions can be supplied with a mounting peg and one fixing hole (type Z).
All types are available with or without wire protectors.
Tab arrangements (See Datasheet)
Type B: 2 tabs 4.8 x 0.8 per way
Type C: 2 tabs 6.3 x 0.8 per way
Type D: 1 tab 6.3 x 0.8 per way
Type E: 4 tabs 2.8 x 0.8 per way
Technical Details
Mouldings: | nylon 6, grey, UL94 V2 |
Contacts: | brass, nickel plated |
Screws: | M3 steel, zinc plated, blue passivated |
Screw tightening torque: | 0.51 Nm |
Temp. limits: | max short term: 140º C continuous: 105º C |
Current rating: | 2.8 tabs: 6A 4.8 tabs: 16A 6.3 tabs: 25A |
Voltage rating: | see approvals |
Tracking distance: | CTI > 600 |
Conductor size: | 4mm2 |
Wire stripping length: | 7mm |
Options
Marking: special printing available. Please provide sketch.